How the LEDs Communicate
The LEDs let you understand the status of the various functions.
The Basic, PRO (ACCESS PRO 8) and LTE control units have a startup time of about 1 minute.
The Light control unit starts up in less than 1 second.
Control Unit LED
During startup
| Light | Color | Message |
|---|---|---|
| On | Red | Powered |
| Blinking | Blue | Startup in progress |
| On | Blue | Startup completed |
| Blinking | Yellow | Sending/receiving message |
| Violet | Violet | Sending/receiving BLE (Light version) |
Command Device LED
| Duration | Color | Message |
|---|---|---|
| 1 sec (default) | Green | Access granted, the entered code or card is authorized. |
| 1.5 sec | Red | Access denied, the entered code or card is NOT authorized. |
| 1 sec (default) | Yellow | Entry queue (relay busy) |
| 1 sec (default) | Yellow | Cloud synchronization completed |
| 50 ms | Yellow | Synchronization successful! Everything OK! |
| Yellow blinking | Yellow | Command device configuration check procedure |
| 1 violet blink | Violet | Synchronization of correct counter/credit operation, and full reset of the counters and/or credits |
| 1 sec | White | Access already granted; for the next 5 seconds (or the time configured in the system) the code is blocked. No log is recorded |